installation
Connect to the electricity supply
(For Fixed Wiring only)
WARNING: This appliance must be
earthed. Only connect to the electrical
mains terminal with the power switched
off. The electrical mains terminal is live.
Follow the terminal block connection
schematic.
Loose and inappropriate connections can
make the terminal overheat.
Ensurethecableclampisttedcorrectly
and securely.
A device must be provided in the
electrical installation which allows the
appliance to be disconnected from the
mains at all poles with a contact opening
ofatleast3mm.
We recommend that the appliance is con-
nected by a competent person who is a
member of a “Competent Person Scheme”
who will comply with the required local
regulations.
Connection should be made with a suit-
able cable.
Important: Ensure that you route all
mains electrical cables well away from any
adjacent heat source, such as an oven or
grill.
Strip the wires & connect to the terminal
block as shown in the terminal block
schematic.
Fit the cable clamp & secure with the
screw provided.
Close the terminal box, ensuring that the
cover is engaged on the locking tabs.
1
2
3
4
N
5
6
N
Live
Live
1
2
3
4
Neutral
Earth
BROWN / L1
BLUE / N
GREEN/YELLOW / PE
230V.....240V
5
6
Cable clamp screw
Cable clamp
Terminal Block Connection
7
Link
7
Note; Ensure Link screw connections are tight!
N
Live
Live
1
2
3
4
Neutral
Earth
BROWN / L2
BLUE / N
GREEN/YELLOW / PE
230V.....240V
5
6
Cable clamp screw
Cable clamp
BLACK / L1
SINGLE PHASE OPTION
3 PHASE OPTION
Vista de página 17